Online Propylene Detector
Online Propylene Detector

Product Overview:

Product overview: Hanyao Electronics fixed on-line propylene detector adopts intelligent imported sensors. It is an intelligent high-performance detection instrument that can continuously monitor propylene gas and has real-time alarm function.The overall explosion-proof structure of the instrument has stable signal, high sensitivity and precision.Explosion-proof grade Exd II CT6.The detector can realize real-time concentration display on the computer through the gas alarm controller and monitoring management software, and can also transmit real-time detection data and alarm status to the safety control center through the optional wireless module.Can be widely used in metallurgy, petroleum and petrochemical, municipal, chemical, shipbuilding, process control and other industries.
Parameters: ◆Original imported high-performance electrochemical propylene sensor, with a service life of more than 2-3 years;
Parameters: ◆Embedded 32-bit ultra-low power consumption microprocessor, fast response, high measurement accuracy, good stability and repeatability;
Parameters: ◆Built-in temperature and humidity sensor, real-time display of ambient temperature and humidity (optional);
Parameters: ◆Intelligent temperature and humidity and zero point compensation algorithm, full software automatic calibration function for target points from level 3 to level 8 to ensure the accuracy of measurement results; automatically detect the working status of each sensor and components when starting up;
Parameters: ◆Automatic protection function against high-concentration gas impact, with good anti-interference performance;
Product characteristics and parameters ▼

Product features: 

◆ Three-wire 4 20mA output and RS485 signal output, relay output, independent air chamber structure, two cable inlets, convenient for on-site installation; 

◆ Large and clear background light can display measurement under any lighting conditions Information, simple and easy-to-understand UI icon menu, friendly user operation interface, showing the humanization and internationalization of the design; 

◆ Support PPM %VOL mg/m3 mg/L concentration unit free switching; 

◆ The instrument is equipped with an infrared remote control , through the remote control to achieve full menu operation, no need to open the cover, simple and convenient; 

◆ Real-time data transmission, accurately send out local and remote wireless alarm notifications with 3-5 alarm methods, and keep the safety under control; 

◆ The air chamber adopts military quality High-strength aluminum profiles, wear-resistant and corrosion-resistant, suitable for complex and harsh industrial environments, reasonable and scientific air chamber design, to ensure the accuracy of real-time monitoring of sensors; 

◆ Short-distance RTU wireless transmission mode or unlimited distance anywhere The GPRS wireless transmission method can transmit real-time detection data and alarm status to the safety center through the built-in wireless module function (optional);

◆ The explosion-proof grade is Exd II CT6 , certified by the National Explosion-proof Electrical Inspection Center .

Product parameters:

product name

Online Propylene Detector

Product number

AGP800-C3H6

Gas detection

Propylene (C3H6) in air

Detection principle

Principles of Electrochemistry

Measuring range

0~100ppm, 500ppm, 1000ppm, 0~100%LEL optional

resolution

0.01ppm (0-100ppm); 0.1ppm (0-1000ppm); 0.1%LEL (0-100%LEL)

Sampling method

①Free diffusion—on-line continuous detection, free diffusion detection method;

②Suction type—external air pump can be equipped with a flow-through adapter for air in and out or a built-in air pump to realize the pump-suction detection method (air pump is optional)

installation method

Wall-mounted type; pipe type (sub-holding type, intubation type, pipe type external thread: M45X1.5mm, optional pipe adapter screw joint, can be welded);

Indication error

≤±3% FS (higher accuracy requirements based on sensor performance)

repeatability

≤±1%

zero drift

≤±1% (FS/year)

Response time

≤20 seconds (T90), (higher requirements based on sensor performance)

Recovery Time

≤30 seconds (higher requirements based on sensor performance)

Power supply

12~30VDC

Power

≤2.5W(DC24V)

Environmental pressure

86kPa~106kPa

ambient temperature

-20°C~+55°C (typical value) -40°C~+70°C (limit value)
(Higher temperature and humidity detection environment can choose our pre-treatment gas monitoring system)

environment humidity

10%~95%RH (no condensation)

The main material

①Shell: ADC12 aluminum alloy, Teflon paint, wear-resistant and corrosion-resistant (316 stainless steel shell is optional for complex and harsh environments)
②Gas chamber: high-strength wear-resistant and corrosion-resistant aluminum profiles, durable (optional for complex and harsh environments With 316 stainless steel air chamber), the outer thread of the air chamber is M45*1.5;

output signal

① Three-wire 4-20mA current signal output, which can be connected to various alarm controllers, PLC, DCS and other control systems;
② RS-485 digital signal output, connected to RS232 adapter card to view and store data on the computer;
③ 2 sets of relays High and low section alarm switch output (standard configuration 1 group, optional 1 group): passive contact, capacity 30V 1A, 125VAC 0.5A;

Signal transmission method

① Three-core (four-core) shielded cable transmission: the farthest transmission distance is 1000 meters to 2000 meters (single core 1 square shielded cable)
; Network long-distance real-time transmission (optional);
③ Optical fiber transmission: the longest transmission can be 20 kilometers to 40 kilometers (optical cable single-mode multi-core transmission, must be equipped with optical fiber MODEM), can be networked (optional);
④ Short distance
RTU433 wireless transmission: the transmission distance is 0 to 2 kilometers, depending on the transmission power and the site environment (optional); optional);

Alarm method

Sound and light alarm, optional sound and light alarm, alarm sound: < 90 decibels

Alarm point setting

A1 alarm value, A2 alarm value;

display screen

LCD liquid crystal display

button mode

Remote control + 3 key operation

direct reading

Measurements

calibration

Full software target point calibration function, calibration calibration value can be set, one-key zero adjustment

Explosion-proof electrical connection thread

① NPT3/4 to internal thread (optional 1/2NPT, G3/4, G1/2 to internal thread)
② Explosion-proof cable stuffing box (optional, explosion-proof certification);

Explosion-proof mark

Ex d II CT6 Gb
(National Explosion-proof Electrical Products Quality Supervision and Inspection Center Inspection and Certification)

degree of protection

IP65

size

210mm high x 175mm wide x 85mm thick  

weight

About 1.8Kg (aluminum alloy shell)

Executive standard

GB15322.1-2003, GB3836.1-2010, GB3836.2-2010, GB3836.4-2010

quality assurance

One year warranty period, free maintenance during the warranty period.